@Random_Seed@bitbang.social On low, most box fans will provide 200-300 cfm of cleaned air, aka a CADR of 200-300 cfm. Each Arctic P14 fan provides 60-70 cfm. So, it depends on how many are installed in the unit, but a 5-pack of fans would provide about 300-350 cfm. Below is the link to a calculator for determining the ACH (Air Changes per Hour) of a given CADR air cleaner in a given size space. The target for wildfire smoke clearing is an ACH of 6+. https://freshairpicks.com/ach-calculator/

Replies (1)

  • @Texan_Reverend@kind.social 2026-07-17 10:01

    @Random_Seed@bitbang.social An air cleaner with a CADR of 300cfm would hit an ACH of 6 in a 375 square foot room with 8 foot ceilings. The ACH will be even higher in rooms which are smaller than that. A decent shortcut is to aim for a CADR of 1cfm for every 1 square foot of space with 8-10 foot ceilings. Any taller, and you need to upsize. So, a 200 ft² room would need 200cfm, a 325 ft² room would need 325cfm, and so on. That saves you from having to use the calculator website all the time.